Benchmarking: Difference between revisions

From IVS Expert Wiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 2: Line 2:


PC 1:  
PC 1:  
* This PC meets or exceeds all of the [https://www.industrialvibes.com/wiki/index.php/Installation#Computer_Requirements recommended specifications].
* This laptop meets or exceeds all of the [https://www.industrialvibes.com/wiki/index.php/Installation#Computer_Requirements recommended specifications].
* HP Victus 16.1 (16-r0153TX) (obtained June 2024 for AU$1900)
* HP Victus 16.1 (16-r0153TX) (obtained June 2024 for AU$1900)
* 32GB RAM
* 32GB RAM
Line 11: Line 11:


PC 2:
PC 2:
* This laptop just meets the minimum requirements.
* Lenovo V145-15AST
* Lenovo V145-15AST
* 8GB RAM
* 8GB RAM

Revision as of 01:51, 1 July 2024

This page contains results of benchmarking tests that allow you to compare the speed and functionality of the software with other products. It also gives more information on the computer specification requirements and how much difference they make to run speed.

PC 1:

  • This laptop meets or exceeds all of the recommended specifications.
  • HP Victus 16.1 (16-r0153TX) (obtained June 2024 for AU$1900)
  • 32GB RAM
  • 1 TB SSD
  • 13th Gen Intel(R) Core(TM) i7-13700HX 2.10 GHz (AVX2 support)
  • NVIDIA GeForce RTX 4060 8GB GDDR6 (Open GL 4.6, compute capability 8.9)
  • 64 bit Windows 11 Home (23H2)

PC 2:

  • This laptop just meets the minimum requirements.
  • Lenovo V145-15AST
  • 8GB RAM
  • 256 GB SSD
  • AMD A4-9125 RADEON R3, 4 Cores, 2.3 GHz
  • Integrated graphics (ie no separate graphics card)
  • 64 bit Windows 10 Home (22H2)

Test 1:

  • National Instruments NI cDAQ-9178 carrier with 4 X NI-9234 modules
  • 16 IEPE channels
  • Maximum sample rate (51.2 kHz)
  • Continuous logging with no gaps in the data.
  • 16 separate FFT plots with current and peak hold spectra
  • 1 Hz frequency resolution, FFT X axis from 0 to 200 Hz
  • Full screen display with 2 columns
  • This requires 12 mouse clicks and 3 keystrokes to set up

Test 2: same as test 1, but with only 12 channels and 12 plots

Test 1 on PC 1:

  • Software startup time: < 30 seconds
  • Setup time: approximately 40 seconds
  • Hardware delay (from finished setup to first plot appearing, this is mostly the time required for hardware to initialise): 70 seconds
  • Screen update rate: approximately one screen update (all 16 plots) every 9 seconds
  • Logging duration: limited only by hard drive space. Approximately 24 GB of data is collected every hour.

Test 1 on PC 2:

  • Software startup time: 220 seconds
  • Setup time: approximately 40 seconds
  • Hardware delay: 75 seconds
  • Screen update rate: approximately one screen update (all 16 plots) every 7 seconds
  • Logging duration: approximately 90 seconds - could not log indefinitely at this rate.

Test 2 on PC 2:

  • Software startup time: 200 seconds
  • Setup time: approximately 40 seconds
  • Hardware delay: 55 seconds
  • Screen update rate: approximately one screen update (all 12 plots) every 5 seconds
  • Logging duration: limited only by hard drive space.